MATERIAL SAFETY DATA SHEET
Finished Product
Date Issued:
01/03/2003
MSDS No:
2102-GHV/5GHV
Date Revised:
07/20/2010
Revision No:
Fine-L-Kote SR (High Viscosity)
1. PRODUCT AND COMPANY IDENTIFICATION
PRODUCT NAME: Fine-L-Kote SR (High Viscosity)
PRODUCT DESCRIPTION: Silicone Conformal Coating (High Viscosity)
PRODUCT CODE: 2102-GHV/5GHV
PRODUCT FORMULATION NAME: Fine-L-Coat™ SR (High Viscosity)
ACTIVE INGREDIENT(S): 1-(2-Methoxy-Methyl-Ethoxy)-2-Propanol Acetate; Polysiloxane mixture;
Benzene- methyl, (Toluene)
MANUFACTURER
24 HR. EMERGENCY TELEPHONE NUMBERS
Techspray, L.P.
1001 N.W. 1st Street
P.O. Box 949
Amarillo TX 79107
Emergency Contact: Chemtrec
Product Stewardship: 1-800-858-4043
Service Number: 1-800-858-4043
CHEMTREC (US Transportation) :
(800) 424 - 9300
CANUTEC (Canadian Transportation) :
(613) 996 - 6666
Emergency Phone :
(800) 858 - 4043
2. HAZARDS IDENTIFICATION
HAZARD DESIGNATION
"F+" - Extremely flammable
R12 - Extremely flammable.
"Xn" - Harmful
R20/21/22 - Harmful by inhalation, in contact with skin and if swallowed.
EMERGENCY OVERVIEW
PHYSICAL APPEARANCE: Transparent, colorless liquid.
IMMEDIATE CONCERNS: Flammable liquid and vapor.
POTENTIAL HEALTH EFFECTS
EYES: Substance causes substantial eye irritation.
SKIN: Prolonged or repeated contact can result in defatting and drying of the skin which may result in
skin irritation and dermatitis (rash).
INGESTION: Harmful if swallowed.
INHALATION: High concentrations in immediate area can displace oxygen and can cause dizziness,
unconsciousness, and possibly death with longer exposure. Keep people away from such vapors
without self-contained breathing apparatus.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
EYES: Symptoms of overexposure include: stinging, tearing, redness and pain.
INGESTION: For large amounts; abdominal pain, nausea and vomiting.
Page 1 of 7
Documentation Provided By HMC Electronics
33 Springdale Ave. Canton, MA 02021
http://www.hmcelectronics.com
(800) 482-4440
Page view 0
1 2 3 4 5 6 7

Summary of Contents

Page 1 - MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEETFinished ProductDate Issued: 01/03/2003MSDS No: 2102-GHV/5GHVDate Revised: 07/20/2010Revision No: 5Fine-L-Kote SR (High Visc

Page 2

MATERIAL SAFETY DATA SHEETFinished ProductDate Issued: 01/03/2003MSDS No: 2102-GHV/5GHVDate Revised: 07/20/2010Revision No: 5Fine-L-Kote SR (High Visc

Page 3

MATERIAL SAFETY DATA SHEETFinished ProductDate Issued: 01/03/2003MSDS No: 2102-GHV/5GHVDate Revised: 07/20/2010Revision No: 5Fine-L-Kote SR (High Visc

Page 4

MATERIAL SAFETY DATA SHEETFinished ProductDate Issued: 01/03/2003MSDS No: 2102-GHV/5GHVDate Revised: 07/20/2010Revision No: 5Fine-L-Kote SR (High Visc

Page 5

MATERIAL SAFETY DATA SHEETFinished ProductDate Issued: 01/03/2003MSDS No: 2102-GHV/5GHVDate Revised: 07/20/2010Revision No: 5Fine-L-Kote SR (High Visc

Page 6

MATERIAL SAFETY DATA SHEETFinished ProductDate Issued: 01/03/2003MSDS No: 2102-GHV/5GHVDate Revised: 07/20/2010Revision No: 5Fine-L-Kote SR (High Visc

Page 7

MATERIAL SAFETY DATA SHEETFinished ProductDate Issued: 01/03/2003MSDS No: 2102-GHV/5GHVDate Revised: 07/20/2010Revision No: 5Fine-L-Kote SR (High Visc

Comments to this Manuals

No comments